For Sullair LS-20S oil separator replacement, the discharge-system parts list shows 250034-085 for the primary separator and 02250048-734 for the secondary separator. The manual’s maintenance note shows a different secondary number, 02250047-734. Verify the applicable parts list using your compressor’s serial number before ordering, then request each confirmed element and its gaskets on a separate line. Sullair LS-20S Operator’s Manual and Parts List, §8.8
Which separator is primary, 250034-085 or 02250048-734?
| Reference in the published parts list | Position | What to confirm in the quote |
|---|---|---|
| 250034-085 | Primary air/oil separator element | Element reference, correct application and whether the matching gaskets are included |
| 02250048-734 | Secondary air/oil separator element | Serial-specific confirmation, matching gaskets and separate quantity |
The service note in §8.8 lists replacement elements with gaskets for both positions. That describes the service items in the manual. A replacement supplier’s quotation should state the contents of its own offer so purchasing can compare an element-only price with a complete service item. Sullair LS-20S parts list, §8.8
Why the secondary number needs a serial-number check
One maintenance note in the publicly available manual shows 02250047-734, while the same manual’s service-parts table and discharge-system parts list use 02250048-734. A YCRT purchasing specification also lists 02250048-734 as the secondary separator for the specific LS 20-150 machine it describes. These documents help explain the discrepancy. If your existing label or paperwork shows the other number, record both references and ask for the current serial-specific parts list or written confirmation before ordering. Sullair LS-20S manual, §§7 and 8 · YCRT procurement specification
Sullair LS-20S oil separator replacement checklist
- Identify the compressor. Include the full model and serial from the machine nameplate. If your team maintains several LS-series units, include the asset number used on the work order.
- Identify each position. Attach a separate label or part photo for the primary and secondary elements when available. State whether maintenance has requested one position or both.
- Ask for the gasket contents. Specify which gaskets are required for each element. Ask the supplier to list the included items and state if anything must be ordered separately.
- Confirm the quantity by asset. For stock or several maintenance jobs, keep the primary and secondary totals separate and show which machines they are intended for.
- Keep the approved cross-reference. File the confirmed part numbers, kit contents and supplier quote with the asset record so the next service does not restart from a handwritten label.
Example enquiry wording for a machine whose parts list confirms both numbers:
Please quote the primary separator reference 250034-085 and the secondary separator reference 02250048-734 as separate lines for the compressor on the attached nameplate. Confirm fitment by serial number and state the gasket contents and quantity for each line.
See Kepuke’s replacement air/oil separator for Sullair reference 250034-085. If you also need a secondary element, send the nameplate and both installed references for a part-specific check.